| Property | Testing Method | Unit | Range of Value |
| Hardness | ISO 7619 | Shore A/Shore D | 50A~93A |
| Density | ISO 2781 | g/cm³ | 0.93~0.98 |
| Tensile Strength | ISO 37 | MPa | 4.5~15.0 |
| Elongation at Break | ISO 37 | % | ≥400 |
| Tear Strength | ISO 34-1 | KN/m | ≥25 |
| Brittle Temperature | ISO 812 | °C | ≤ -50 |
| Fogging Test | ISO 6452 | mg | ≤2.0 |
| Xenon Lamp Test | ISO 4892 | level | ≥4 |
| Ozone Resistance | ISO 1431 | - | No crack |
| Property | Testing Method | Unit | Range of Value | |
|---|---|---|---|---|
| Hardness | ISO 7619 | Shore A/Shore D | 40A~50D | |
| Density | ISO 2781 | g/cm³ | 0.93~0.98 | |
| Tensile Strength | ISO 37 | MPa | 3.8~24.0 | |
| Elongation at Break | ISO 37 | % | ≥400 | |
| Tear Strength | ISO 34-1 | KN/m | ≥20 | |
| Brittle Temperature | ISO 812 | °C | ≤ -50 | |
| Xenon Lamp Test | ISO 4892-2 | level | ≥4 | |
| Ozone Resistance | ISO 1431 | - | No crack | |
| 150℃*500h Heating aging | Change in hardness | ISO 188 | Shore A | -2~+2 |
| Change in tensile strength | % | ≤10 | ||
| Elongation at break | % | ≤10 | ||